Hao Zhu, Yijun Chen, Changshun Huanga, Yangyang Han, Yiwei Zhang, Shucan Xie. Simultaneous determination of four Sudan dyes in rat blood by UFLC-MS/MS and its application to a pharmacokinetic study in rats☆[J]. Journal of Pharmaceutical Analysis, 2015, 5(4): 239-248. doi: 10.1016/j.jpha.2015.03.001
Citation:
Hao Zhu, Yijun Chen, Changshun Huanga, Yangyang Han, Yiwei Zhang, Shucan Xie. Simultaneous determination of four Sudan dyes in rat blood by UFLC-MS/MS and its application to a pharmacokinetic study in rats☆[J]. Journal of Pharmaceutical Analysis, 2015, 5(4): 239-248. doi: 10.1016/j.jpha.2015.03.001
Hao Zhu, Yijun Chen, Changshun Huanga, Yangyang Han, Yiwei Zhang, Shucan Xie. Simultaneous determination of four Sudan dyes in rat blood by UFLC-MS/MS and its application to a pharmacokinetic study in rats☆[J]. Journal of Pharmaceutical Analysis, 2015, 5(4): 239-248. doi: 10.1016/j.jpha.2015.03.001
Citation:
Hao Zhu, Yijun Chen, Changshun Huanga, Yangyang Han, Yiwei Zhang, Shucan Xie. Simultaneous determination of four Sudan dyes in rat blood by UFLC-MS/MS and its application to a pharmacokinetic study in rats☆[J]. Journal of Pharmaceutical Analysis, 2015, 5(4): 239-248. doi: 10.1016/j.jpha.2015.03.001
Department of Anesthesia, the First Hospital of Ningbo City, Ningbo 315010, China
Zhejiang Provincial Key Laboratory of Health Risk Appraisal for Trace Toxic Chemicals, Ningbo Municipal Center for Disease Control and Prevention, Ningbo 315010, China
A rapid and sensitive method based on ultrafast liquid chromatography-tandem mass spectrometry was developed and validated for simultaneous determination of Sudan Ⅰ, Sudan Ⅱ, Sudan Ⅲ, and Sudan Ⅳ levels in rat whole blood. Cleanert C18 mixed-mode polymeric sorbent was used for effective solid-phase extraction cleanup. Separation was carried out on a reversed-phase C18 column (100 mm × 2.1 mm, 1.8 μm) using 0.1% (v/v) formic acid in water/0.1% (v/v) formic acid in acetonitrile as the mobile phase in gradient elution. Quantification was performed by an electrospray ionization source in the positive multiple reaction monitoring mode using D5-Sudan I as the internal standard. Calibration curves showed good linearity between 0.2 and 20.0 μg/L, with correlation coefficients higher than 0.9990. The average recovery rates were between 93.05% and 114.98%. The intra- and inter-day relative standard deviations were within 6.2%. The lower limit of quantification was 0.2 μg/L. All the analytes were found to be stable in aseries of stability studies. The proposed method was successfully applied to a pharmacokinetic study of four Sudan dyes after oral administration to rats.