Jinqi Zheng, Xinyu Zhao, Caixia Li, Chenxiao Yan, Pingping Chen, Xiao Gu, Liya Hong, Su Zeng. Development of a dual-chamber derivatization method for the determination of cyanide in sodium nitroprusside and its preparation via HS-GC-ECD[J]. Journal of Pharmaceutical Analysis. doi: 10.1016/j.jpha.2025.101353
Citation: Jinqi Zheng, Xinyu Zhao, Caixia Li, Chenxiao Yan, Pingping Chen, Xiao Gu, Liya Hong, Su Zeng. Development of a dual-chamber derivatization method for the determination of cyanide in sodium nitroprusside and its preparation via HS-GC-ECD[J]. Journal of Pharmaceutical Analysis. doi: 10.1016/j.jpha.2025.101353

Development of a dual-chamber derivatization method for the determination of cyanide in sodium nitroprusside and its preparation via HS-GC-ECD

doi: 10.1016/j.jpha.2025.101353
Funds:

The project was supported by Zhejiang Province Medical Products Administration Science Project, China (Grant No.: 2025021).

  • Received Date: Dec. 18, 2024
  • Rev Recd Date: May 24, 2025
  • Available Online: Jun. 04, 2025
  • The acute toxicity of cyanide and its pharmaceutical residues, has fueled interest in the development of analytical methods for its determination, particularly for sodium nitroprusside (SNP), a widely used vasodilator with potential cyanide residues. In this study, a dual-chamber derivatization bottle was designed to establish an interconnected gas environment, thereby facilitating chloramine T-mediated cyanide conversion to cyanogen chloride (CNCl) without direct contact with SNP. Subsequent determination of the analytes was undertaken using a headspace gas chromatography electron capture detector (HS-GC-ECD). The challenges of analyzing cyanide and the rapid degradation of SNP were addressed simultaneously. The method was subjected to rigorous validation, encompassing specificity, linearity, limits of detection (LOD), limit of quantification (LOQ), accuracy, precision, and robustness. The validation process revealed a notable degree of linearity within the range of 0.012-1.56 μg/mL, with a LOQ of 12.0 ng/mL. The method was found to be both accurate and precise, thus satisfying the requisite criteria. This method facilitates reliable cyanide monitoring in degradation-prone pharmaceuticals.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(1)

    Article Metrics

    Article views (7) PDF downloads(1) Cited by()