Volume 11 Issue 5
Oct.  2021
Turn off MathJax
Article Contents
Karol Jaroch, Paulina Taczyńska, Marta Czechowska, Joanna Bogusiewicz, Kamil Łuczykowski, Katarzyna Burlikowska, Barbara Bojko. One extraction tool for in vitro-in vivo extrapolation? SPME-based metabolomics of in vitro 2D, 3D, and in vivo mouse melanoma models[J]. Journal of Pharmaceutical Analysis, 2021, 11(5): 667-674. doi: 10.1016/j.jpha.2021.03.005
Citation: Karol Jaroch, Paulina Taczyńska, Marta Czechowska, Joanna Bogusiewicz, Kamil Łuczykowski, Katarzyna Burlikowska, Barbara Bojko. One extraction tool for in vitro-in vivo extrapolation? SPME-based metabolomics of in vitro 2D, 3D, and in vivo mouse melanoma models[J]. Journal of Pharmaceutical Analysis, 2021, 11(5): 667-674. doi: 10.1016/j.jpha.2021.03.005

One extraction tool for in vitro-in vivo extrapolation? SPME-based metabolomics of in vitro 2D, 3D, and in vivo mouse melanoma models

doi: 10.1016/j.jpha.2021.03.005
Funds:

This work has been funded by the statutory grant from Nicolaus Copernicus University (Grant No.: 452). We would like to extend our gratitude to Thermo Fisher Scientific (Bremen, Germany) for providing the Q-Exactive Focus.

  • Received Date: Dec. 06, 2020
  • Rev Recd Date: Mar. 01, 2021
  • Available Online: Jan. 11, 2022
  • Publish Date: Oct. 15, 2021
  • Solid phase microextraction (SPME) in combination with high-resolution mass spectrometry was employed for the determination of metabolomic profile of mouse melanoma growth within in vitro 2D, in vitro 3D, and in vivo models. Such multi-model approach had never been investigated before. Due to the low-invasiveness of SPME, it was possible to perform time-course analysis, which allowed building time profile of biochemical reactions in the studied material. Such approach does not require the multiplication of samples as subsequent analyses are performed from the very same cell culture or from the same individual. SPME already reduces the number of animals required for experiment; therefore, it is with good concordance with the 3Rs rule (replacement, reduction, and refinement). Among tested models, the largest number of compounds was found within the in vitro 2D cell culture model, while in vivo and in vitro 3D models had the lowest number of detected compounds. These results may be connected with a higher metabolic rate, as well as lower integrity of the in vitro 2D model compared to the in vitro 3D model resulting in a lower number of compounds released into medium in the latter model. In terms of in vitro-in vivo extrapolation, the in vitro 2D model performed more similar to in vivo model compared to in vitro 3D model; however, it might have been due to the fact that only compounds secreted to medium were investigated. Thus, in further experiments to obtain full metabolome information, the intraspheroidal assessment or spheroid dissociation would be necessary.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (74) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return