Vivekanand A. Chatpalliwara, Pawan K. Porwal, Neeraj Upmanyu. Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation[J]. Journal of Pharmaceutical Analysis, 2012, 02(3): 226-237. doi: 10.1016/j.jpha.2012.01.003
Citation: Vivekanand A. Chatpalliwara, Pawan K. Porwal, Neeraj Upmanyu. Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation[J]. Journal of Pharmaceutical Analysis, 2012, 02(3): 226-237. doi: 10.1016/j.jpha.2012.01.003

Validated gradient stability indicating HPLC method for determining Diltiazem Hydrochloride and related substances in bulk drug and novel tablet formulation

doi: 10.1016/j.jpha.2012.01.003
  • Publish Date: Jun. 10, 2012
  • A stability-indicating liquid chromatographic method has been developed and validated for the determination of Diltiazem Hydrochloride (DTZ) together with its six related substances (Diltiazem sulphoxide,Imp-A,Imp-B,Imp-D,Imp-E,and Imp-F) in a laboratory mixture as well as in a novel tablet formulation developed in-house.Efficient chromatographic separation was achieved on a Hypersil BDS C18 (150mm ×4.6mm,5.0μm) with mobile phase containing 0.2% Triethylamine (TEA) in gradient combination with acetonitrile (ACN) at a flow rate of 1.0 mL/min and the eluent was monitored at 240 nm.In the developed method,the resolution of DTZ from any pair of impurities was found to be greater than 2.0.The test solution and related substances were found to be stable in the diluent for 24 h.The developed method resolved the drug from its known impurities,stated above,and also from additional impurities generated when the formulation was subjected to forced degradation; the mass balance was found close to 99.9%.Regression analyses indicate correlation coefficient value greater than 0.997 for DTZ and its six known impurities.The LOD for DTZ and the known impurities was at a level below 0.02%.The method has shown good,consistent recoveries for DTZ (99.8-101.2%) and also for its six known impurities (97.2-101.3%).The method was found to be accurate,precise,linear,specific,sensitive,rugged,robust,and stability-indicating.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (79) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return