Severino S. Monte-Filho, Stefani I.E. Andrade, Marcelo B. Lima, Mario C.U. Araujo. Synthesis of highly fluorescent carbon dots from lemon and onion juices for determination of riboflavin in multivitamin/mineral supplements[J]. Journal of Pharmaceutical Analysis, 2019, 9(3): 209-216.
Citation:
Severino S. Monte-Filho, Stefani I.E. Andrade, Marcelo B. Lima, Mario C.U. Araujo. Synthesis of highly fluorescent carbon dots from lemon and onion juices for determination of riboflavin in multivitamin/mineral supplements[J]. Journal of Pharmaceutical Analysis, 2019, 9(3): 209-216.
Severino S. Monte-Filho, Stefani I.E. Andrade, Marcelo B. Lima, Mario C.U. Araujo. Synthesis of highly fluorescent carbon dots from lemon and onion juices for determination of riboflavin in multivitamin/mineral supplements[J]. Journal of Pharmaceutical Analysis, 2019, 9(3): 209-216.
Citation:
Severino S. Monte-Filho, Stefani I.E. Andrade, Marcelo B. Lima, Mario C.U. Araujo. Synthesis of highly fluorescent carbon dots from lemon and onion juices for determination of riboflavin in multivitamin/mineral supplements[J]. Journal of Pharmaceutical Analysis, 2019, 9(3): 209-216.
In this work, lemon and onion biomasses commonly found in street markets are for the first time used to develop a facile, fast and low-cost one-step microwave-assisted carbonization method for synthesis of highly fluorescent carbon dots (CDs). The structure and optical properties of CDs were investigated by TEM, XRD, XRF, UV-Vis, FTIR, and fluorescence spectroscopy. CDs displayed satisfactory optical pro-prieties, a high quantum yield of 23.6%, and excellent water solubility, and the particle size was 4.23-8.22 nm with an average diameter of 6.15 nm. An efficient fluorescent resonance energy transfer (FRET) between the CDs and riboflavin was achieved with CDs acting as donor and riboflavin as acceptor. A linear relationship between FRET and the riboflavin concentration from 0.10 to 3.0 μg/mL was observed, allowing the development of an accurate and fast analytical method to determine this vitamin in multivitamin/mineral supplements. Despite the potential interferences in these supplements, CDs were selective for riboflavin under optimized conditions. A paired t-test at a 95% confidence level indicated no statistically significant difference between the proposed and the reference methods. Recovery test presented values ranged from 96.0% to 101.4%. The limit of detection and relative standard deviation were estimated at 1.0 ng/mL and <2.6% (n = 3), respectively. CDs were successfully synthesized in a domestic microwave oven (1450 W, 6 min), presenting satisfactory parameters when compared with results of other studies reported in the literature, suggesting that the proposed method is a potentially useful method for the synthesis of CDs and determination of riboflavin.