Volume 8 Issue 4
Aug.  2018
Turn off MathJax
Article Contents
Yadollah Yamini, Meysam Safari, Maryam Shamsayei. Simultaneous determination of steroid drugs in the ointment via magnetic solid phase extraction followed by HPLC-UV[J]. Journal of Pharmaceutical Analysis, 2018, 8(4): 250-257.
Citation: Yadollah Yamini, Meysam Safari, Maryam Shamsayei. Simultaneous determination of steroid drugs in the ointment via magnetic solid phase extraction followed by HPLC-UV[J]. Journal of Pharmaceutical Analysis, 2018, 8(4): 250-257.

Simultaneous determination of steroid drugs in the ointment via magnetic solid phase extraction followed by HPLC-UV

  • Publish Date: Aug. 10, 2018
  • The copper-coated iron oxide nanoparticles with core-shell were produced by deposition of a Cu shell on Fe3O4 NPs through reduction of Cu2+ ions in solution using NaBH4. Subsequently, the organosulfur compound, bis-(2,4,4-trimethylpentyl)-dithiophosphinic acid (b-TMP-DTPA), was used to form self-assembled monolayer in order to modify sorbent's surface via covalent bonding between Cu and thiol (-SH) terminal groups. The prepared magnetic nanoparticles were characterized by using Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), transmission electron microscope (TEM), vibrating sample magnetometer (VSM) and thermo gravimetric analysis (TGA). Then, the application of this new sorbent was investigated to extract the steroid drugs in ointment samples with the aid of ultrasound.An external magnetic field was applied to collect the magnetic nanoparticles (MNPs). The extracted analytes were desorbed using acetonitrile. The obtained extraction solution was analyzed by HPLC-UV. The main affecting factors on the extraction efficiency including pH, sonication time, amount of sorbent, salt concentration, and desorption conditions were optimized in detail. Under the optimum conditions, good linearity was obtained in the range of 2.5-250.0 μg/ L with reasonable linearity (R2 > 0.99) and the limits of detection (LODs) ranged between 0.5 and 1.0 μg/L (based on S/N = 3). Repeatability (intra-day precision) based on five replicates and preconcentration factors were calculated to be 3.6%-4.7% and 87116,respectively.Relative recoveries in ointment samples at two spiked levels of the target analytes were obtained in the range of 90.0%-103.2%. The results illustrated that the Fe3O4@Cu@ b-TMP-DTPA NPs have the capability of extraction of steroid drugs from ointment samples.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (82) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return