Volume 6 Issue 2
Apr.  2016
Turn off MathJax
Article Contents
Huan Lu, Chong Su, Lei Yin, Liqiang Gu, Jingkai Gu, Xiaohui Chen. Liquid chromatography-tandem mass spectrometry method for simultaneous determination of valproic acid and its ene-metabolites in epilepsy patient plasma$[J]. Journal of Pharmaceutical Analysis, 2016, 6(2): 112-116. doi: 10.1016/j.jpha.2015.11.006
Citation: Huan Lu, Chong Su, Lei Yin, Liqiang Gu, Jingkai Gu, Xiaohui Chen. Liquid chromatography-tandem mass spectrometry method for simultaneous determination of valproic acid and its ene-metabolites in epilepsy patient plasma$[J]. Journal of Pharmaceutical Analysis, 2016, 6(2): 112-116. doi: 10.1016/j.jpha.2015.11.006

Liquid chromatography-tandem mass spectrometry method for simultaneous determination of valproic acid and its ene-metabolites in epilepsy patient plasma$

doi: 10.1016/j.jpha.2015.11.006
  • Publish Date: Apr. 10, 2016
  • A simple and high throughput method was developed and validated for simultaneous determination of valproic acid and its two toxicant ene-metabolites, 2-enevalproic acid and 4-enevalproic acid in epilepsy patient plasma using liquid chromatography–tandem mass spectrometry. Probenecid was used as in-ternal standard and solid-phase extraction was selected for sample preparation. A chromatographic separation was performed on an Agilent Poroshell SB-C18 column (50 mm ? 4.6 mm i.d., 2.7μm) by an optimized gradient elution at a flow rate of 0.9 mL/min. The total run time was 7 min. Electrospray ionization was used in negative ion mode by multiple reaction monitoring of the precursor-to-product ion transitions at m/z 143.0-143.0 for valproic acid, m/z 140.9-140.9 for 2-enevalproic acid and 4-enevalproic acid for their poor fragments, and m/z 283.9-239.9 for probenecid. The results showed good linearity of valproic acid, 2-enevalproic acid and 4-enevalproic acid in their respective linear ranges. The correlation coefficients were more than 0.998. The intra- and inter-day precision of the assay was less than 11.0%and the accuracy ranged from 2%to 12%. This analytical method was successfully applied to assay plasma concentrations of valproic acid and its two ene-metabolites in epilepsy patient plasma and used for therapeutic drug monitoring.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (26) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return