Volume 5 Issue 5
Oct.  2015
Turn off MathJax
Article Contents
Carla M. Teglia, Milagros Montemurro, María M. De Zan, María S. Cámara. Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals[J]. Journal of Pharmaceutical Analysis, 2015, 5(5): 296-306. doi: 10.1016/j.jpha.2015.02.004
Citation: Carla M. Teglia, Milagros Montemurro, María M. De Zan, María S. Cámara. Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals[J]. Journal of Pharmaceutical Analysis, 2015, 5(5): 296-306. doi: 10.1016/j.jpha.2015.02.004

Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals

doi: 10.1016/j.jpha.2015.02.004
  • Publish Date: Oct. 10, 2015
  • An efficient generic static headspace gas chromatography (HSGC) method was developed, optimized and validated for the routine determination of several residual solvents (RS) in drug substance, using a strategy with two sets of calibration. Dimethylsulfoxide (DMSO) was selected as the sample diluent and internal standards were used to minimize signal variations due to the preparative step. A gas chroma-tograph from Agilent Model 6890 equipped with flame ionization detector (FID) and a DB-624 (30 m × 0.53 mm i.d., 3.00μm film thickness) column was used. The inlet split ratio was 5:1. The influ-encing factors in the chromatographic separation of the analytes were determined through a fractional factorial experimental design. Significant variables: the initial temperature (IT), the final temperature (FT) of the oven and the carrier gas flow rate (F) were optimized using a central composite design. Response transformation and desirability function were applied to find out the optimal combination of the chromatographic variables to achieve an adequate resolution of the analytes and short analysis time. These conditions were 30 °C for IT, 158 °C for FT and 1.90 mL/min for F. The method was proven to be accurate, linear in a wide range and very sensitive for the analyzed solvents through a comprehensive validation according to the ICH guidelines.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (113) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return